{"id":612,"date":"2016-06-11T19:21:11","date_gmt":"2016-06-12T02:21:11","guid":{"rendered":"http:\/\/pididu.com\/wordpress\/solarbike\/?p=612"},"modified":"2026-10-27T16:46:25","modified_gmt":"2026-10-27T23:46:25","slug":"synchronous-rectifier-destroyed","status":"publish","type":"post","link":"http:\/\/pididu.com\/wordpress\/solarbike\/synchronous-rectifier-destroyed\/","title":{"rendered":"Synchronous Rectifier Destroyed"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><a href=\"http:\/\/pididu.com\/wordpress\/solarbike\/files\/2016\/06\/Gate-Drive-Experiment.gif\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"537\" src=\"http:\/\/pididu.com\/wordpress\/solarbike\/files\/2016\/06\/Gate-Drive-Experiment.gif\" alt=\"scope probe connections\" class=\"wp-image-618\"\/><\/a><figcaption class=\"wp-element-caption\">Simplified depiction of the power transfer schematic. Note that scope common is on a node that varies with respect to system ground.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Q2, a MOSFET acting as a synchronous rectifier, had burned out in a previous experiment. &nbsp;I put a scope on the gate to see what was going on.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><a href=\"http:\/\/pididu.com\/wordpress\/solarbike\/files\/2016\/05\/Gate-Drive-3-turns.gif\"><img loading=\"lazy\" decoding=\"async\" width=\"732\" height=\"504\" src=\"http:\/\/pididu.com\/wordpress\/solarbike\/files\/2016\/05\/Gate-Drive-3-turns.gif\" alt=\"synchronous rectifier gate drive\" class=\"wp-image-613\"\/><\/a><figcaption class=\"wp-element-caption\">The yellow trace is channel 1, and the green trace is channel 2 (the gate drive) Previouly, the gate drive winding had 4 turns &#8211; this was reduced to 3 turns when this trace was taken.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">The interval during which channel 1 (yellow) is +24 volts is when Q3 is on. &nbsp;When Q3 turns off, the signal goes negative relative to scope ground, as energy is transferred to the output. &nbsp;At the same time, the gate drive (channel 2, green) turns on. &nbsp;As there is considerable ringing in the circuit, the gate drive spikes to almost 20 volts initially &#8211; the maximum allowable voltage on the Q2 gate. &nbsp;Before the gate winding was reduced from 4 turns to 3, this spike would have theoretically reached about 27 volts. &nbsp;That is probably what destroyed the original Q2 after a few minutes of operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Even with the gate winding at 3 turns, there is too little margin for this engineer&#8217;s comfort. If the output voltage was higher, the gate drive on Q2 would again exceed the 20 volt spec. I&#8217;m beginning to realize why we don&#8217;t see self-timed synchronous rectification with inverting converters.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The design is very sensitive to selection of analog components. If the gate is not driven hard enough, no synchronous rectification goes on.<\/li>\n\n\n\n<li>If the gate is driven too hard, when the converter goes into discontinuous operation, massive amounts of energy are lost as the output discharges into the input.<\/li>\n\n\n\n<li>The cutoff of the gate drive is dependent on an RC decay, so will never be as efficient as a rectangular pulse with optimum timing.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">I think I&#8217;m going to go to a digitally-timed gate drive. To do the level translation, I will need a pulse transformer winding for every gate (there are 12 in the actual design).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But the real reason I demurred or a digital solution was the PICAXE. Using PICAXE BASIC, it is not possible to generate the timing pulse for Q3, and also a pulse with the right phase and duration for Q2. The actual PIC is capable of such output, but that would force me into abandoning BASIC and (possibly) in-circuit programming, too.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Q2, a MOSFET acting as a synchronous rectifier, had burned out in a previous experiment. &nbsp;I put a scope on the gate to see what was going on. The interval during which channel 1 (yellow) is +24 volts is when Q3 is on. &nbsp;When Q3 turns off, the signal goes negative relative to scope ground, &hellip; <a href=\"http:\/\/pididu.com\/wordpress\/solarbike\/synchronous-rectifier-destroyed\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Synchronous Rectifier Destroyed<\/span> <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2],"tags":[],"class_list":["post-612","post","type-post","status-publish","format-standard","hentry","category-electrical"],"_links":{"self":[{"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/posts\/612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/comments?post=612"}],"version-history":[{"count":0,"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/posts\/612\/revisions"}],"wp:attachment":[{"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/media?parent=612"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/categories?post=612"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/pididu.com\/wordpress\/solarbike\/wp-json\/wp\/v2\/tags?post=612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}